No. Knowing the name of an acid does not mean that a stainless steel or plastic pump is compatible. You need to check the concentration, the temperature, the actual composition of the product, and every component that touches the fluid.
At INDNOVA we get this question all the time. This video explains why stainless steel is not a universal answer and what data to gather before asking.
Why isn’t it enough to know which acid it is?
Stainless steel is not a universal answer. The same acid can behave differently if its composition or temperature changes.
That is why the right question is not “which acid is it?” but “under what conditions will I be pumping it?”.
Which parts of the pump need to be checked?
You have to look at the whole pump, not just the body. The parts in contact with the product can be the impeller, the shaft, the elastomers, the diaphragms, and the mechanical seals, depending on the technology used.
It only takes one of them being incompatible for the equipment to fail early.
What happens if the fluid carries particles?
Another piece of data must be added: their size, their concentration, and whether they are abrasive.
What data should be gathered before asking?
Before asking, have four pieces of data at hand: the product composition, the concentration, the operating temperature, and the presence of solids.
Conclusion
No material works for every acid. Compatibility depends on the concentration, the temperature, and every component that touches the fluid.
Frequently Asked Questions
Is a stainless steel pump suitable for any acid?
No. Stainless steel is not a universal answer.
Is knowing the name of the acid enough?
No. You need to check the concentration, the temperature, the actual composition of the product, and every component that touches the fluid.
Why can the same acid behave differently?
Because its composition or its temperature can change.
Which parts of the pump come into contact with the product?
Depending on the technology, they can be the impeller, the shaft, the elastomers, the diaphragms, and the mechanical seals.
What data should be gathered before asking?
Product composition, concentration, operating temperature, and the presence of solids.