Why Does a Centrifugal Pump Cavitate?

Manuel Vargas, Application Engineer

A centrifugal pump cavitates when the local pressure of the liquid drops below its vapor pressure. Vapor bubbles form and then collapse as they move into zones of higher pressure. This can cause noise, vibration, loss of performance, and erosion of components.

At INDNOVA we explain step by step why a centrifugal pump cavitates. This video explains what happens inside the pump, why suction matters, and what to check.

What happens inside the pump when it cavitates?

As it approaches the impeller, the liquid passes through regions where the pressure can drop significantly. If that pressure falls below the vapor pressure of the liquid at its operating temperature, vapor cavities form.

When those bubbles reach a zone of higher pressure, they collapse. If this repeats, it can damage the surfaces and affect operation.

Is cavitation the same as air entering through the suction?

No. Air entering through a leak in the suction has different physical causes and is checked differently.

Why does suction matter?

A pump is not sized only to deliver flow and pressure at the discharge: it also needs to receive the fluid.

When the suction is not validated, installing a larger pump may solve nothing and can even make operating conditions worse.

What should be checked?

Check the level and pressure of the feed tank, the product temperature, the restrictions and filters in the suction, and the operating point against the manufacturer’s curve.

Conclusion

Cavitation is a suction pressure problem. The solution is to correct the cause, not just the symptom.

Frequently Asked Questions

What is cavitation in a centrifugal pump?

It happens when the local pressure of the liquid drops below its vapor pressure. Vapor bubbles form and then collapse as they move into zones of higher pressure.

What can cavitation cause?

Noise, vibration, loss of performance, and erosion of components.

Are cavitation and air entering through the suction the same thing?

No. They have different physical causes and are checked differently.

Does a larger pump solve cavitation?

Not necessarily. If the suction is not validated, a larger pump may solve nothing and can even make operating conditions worse.

What should be checked if cavitation is suspected?

The level and pressure of the feed tank, the product temperature, the restrictions and filters in the suction, and the operating point against the manufacturer’s curve.