INDNOVA (Logo)

Main navigation

What Should I Check When My Pump Starts Delivering Less Flow? (Banner)
Maintenance

What Should I Check When My Pump Starts Delivering Less Flow?

Manuel Vargas, Application Engineer

Check in this order: measure the real flow rate, compare pressures, check filters, valves, and pipes, and check the speed or the air supply. Verify whether the fluid has changed. Only at the end investigate internal wear.

Before ordering spare parts, rule out the installation. In this video, the INDNOVA team gives the diagnostic order in six steps.

Step 1: How much liquid is really being transported?

Confirm with a reliable measurement how much liquid the pump is actually transporting.

Step 2: Which pressures should be compared?

Compare the suction and discharge pressure with the design conditions.

Step 3: Which parts of the installation should be checked?

Check filters, valves, pipes, and tank levels. A new restriction lowers the flow rate.

Step 4: What should be checked on the drive?

Check the rotation speed if it is a motor-driven pump. If it is an air-operated pump, check the air supply.

Step 5: Did the fluid change?

Verify whether the temperature, viscosity, or composition of the fluid changed.

Step 6: When should internal wear be investigated?

If conditions are comparable to before, only then investigate wear or other internal failures, using the manufacturer’s manual.

What should you do if the pump never reached the expected flow rate?

If the pump has never reached the expected flow rate since it was installed, start with the selection and the system curve.

What if it used to perform and now it doesn’t?

The question is what condition changed. That narrows down the diagnosis.

Conclusion

When flow is lost: measure, compare pressures, check the installation, check the drive, check the fluid, and only then look for internal wear. Before ordering spare parts, rule out the installation. INDNOVA can help.

Frequently Asked Questions

What should be checked first when a pump loses flow?

Measure the real flow rate with a reliable measurement.

Why is the installation ruled out before ordering spare parts?

Because a new restriction lowers the flow rate.

What should be checked on an air-operated pump?

The air supply. On a motor-driven pump, the rotation speed.

When is internal wear investigated?

At the end, if conditions are comparable to before, using the manufacturer’s manual.

What should you do if the pump never reached the expected flow rate?

Start with the selection and the system curve.

What if it used to perform and now it doesn’t?

You have to ask what condition changed. That narrows down the diagnosis.

Published November 10, 2026